産品中(zhōng)心

一(yī)步法人中(zhōng)性粒細胞明膠酶關聯脂質運載蛋白(bái)(NGAL)酶聯免疫吸附檢測試劑盒
ELK038ES
規格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: EasyStep Human NGAL(Neutrophil Gelatinase Associated Lipocalin) ELISA Kit
Reactivity: Human
Alternative Names: LCN2; p25; Lipocalin 2; Oncogene 24p3; 25 kDa alpha-2-microglobulin-related subunit of MMP-9; Siderocalin LCN2
Assay Type: Sandwich
Sensitivity: 5.6 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: Serum, plasma
Assay Length: 1.5h
Research Area: Infection immunity;Urology;
Uniprot ID: P80188
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human NGAL, and the Human NGAL standard plate wells that pre-coated using protein-related techniques are provided separately. Standard/Sample Diluent Buffer or samples are added to the appropriate microtiter plate wells ,then added a HRP-conjugated antibody specific to Human NGAL. After TMB substrate solution is added, only those wells that contain Human NGAL and HRP-conjugated antibody will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human NGAL in the samples is then determined by comparing the OD of the samples to the standard curve.

标準曲線

Concentration (pg/mL) OD Corrected OD
1000.00 2.153 2.045
500.00 1.515 1.407
250.00 1.106 0.998
125.00 0.928 0.820
62.50 0.563 0.455
31.25 0.426 0.318
15.63 0.156 0.048
0.00 0.108 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant NGAL and the recovery rates were calculated by comparing the measured value to the expected amount of NGAL in samples.
Matrix Recovery range Average
serum(n=5) 94-105% 98%
EDTA plasma(n=5) 94-107% 100%
Heparin plasma(n=5) 82-95% 88%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of NGAL and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 90-98% 85-92% 83-96% 93-102%
EDTA plasma(n=5) 85-94% 87-96% 82-93% 89-103%
Heparin plasma(n=5) 85-92% 83-101% 87-98% 79-92%

産品成分(fēn)表

關閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術支持

關注微信公衆号

微信掃一(yī)掃立即咨詢

微信掃一(yī)掃立即咨詢

關閉