人髓過氧化物(wù)酶(MPO)酶聯免疫吸附檢測試劑盒
ELK1062
規格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human MPO(Myeloperoxidase) ELISA Kit
Reactivity: Human
Alternative Names: Mpo; Myeloperoxidase ; MPO
Assay Type: Sandwich
Sensitivity: 0.65 ng/mL
Standard: 100 ng/mL
Detection Range: 1.57-100 ng/mL
Sample Type: Serum, plasma and other biological fluids.
Assay Length: 3.5h
Research Area: Enzyme & Kinase;Infection immunity;Cardiovascular biology;Hepatology;
Uniprot ID: P05164
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human MPO. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human MPO. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human MPO, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human MPO in the samples is then determined by comparing the OD of the samples to the standard curve.

标準曲線

Concentration (ng/mL) OD Corrected OD
100.00 1.954 1.806
50.00 1.588 1.440
25.00 1.276 1.128
12.50 0.943 0.795
6.25 0.623 0.475
3.13 0.354 0.206
1.57 0.247 0.099
0.00 0.148 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant MPO and the recovery rates were calculated by comparing the measured value to the expected amount of MPO in samples.
Matrix Recovery range Average
serum(n=5) 82-95% 88%
EDTA plasma(n=5) 94-107% 100%
Heparin plasma(n=5) 78-92% 85%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of MPO and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-92% 83-101% 87-98% 79-92%
EDTA plasma(n=5) 95-103% 91-105% 78-90% 89-97%
Heparin plasma(n=5) 85-94% 87-96% 82-93% 89-103%