産品中(zhōng)心

人糖胺聚糖(GAGs)酶聯免疫吸附檢測試劑盒
ELK9843
規格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻

Product name: Human GAGs(Glycosaminoglycan) ELISA Kit
Reactivity: Human
Alternative Names: Mucopolysaccharide; GAGs;
Assay Type: Competitive Inhibition
Sensitivity: 0.53 ng/mL
Standard: 100 ng/mL
Detection Range: 1.57-100 ng/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 2h
Research Area: Tumor immunity;Hepatology;
Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Human GAGs protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human GAGs. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human GAGs in the samples is then determined by comparing the OD of the samples to the standard curve.

标準曲線

Concentration (ng/mL) OD Corrected OD
100.00 0.199
50.00 0.367
25.00 0.589
12.50 0.857
6.25 1.253
3.13 1.557
1.57 1.733
0.00 2.213

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant GAGs and the recovery rates were calculated by comparing the measured value to the expected amount of GAGs in samples.
Matrix Recovery range Average
serum(n=5) 83-98% 90%
EDTA plasma(n=5) 85-97% 91%
Heparin plasma(n=5) 92-107% 99%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of GAGs and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 91-102% 98-107% 93-102% 80-93%
EDTA plasma(n=5) 91-100% 89-97% 87-98% 85-92%
Heparin plasma(n=5) 97-103% 87-98% 95-102% 81-103%